Electric shock

0056/06

imageimageimage
Case number
0056/06
Category
Lighting equipment
Audience
Consumer
Notifying country
🇭🇺 Hungary
Country of origin
Türkiye
Published
2006-02-10

⚠️ Risk

The basic insulated internal wiring was led through sharp and burring edges. The wire of the conductor connected to the terminal gets into contact with accessible metal live parts. There was neither protective earth provided with the luminaire nor indication of Class II. Since the protective earth is missing accessible metal parts get into contact with basic insulated conductors (double insulation is missing). These products do not comply with the LVD Directive and the European Standards.

Measures

Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Withdrawal from the market and recall ordered by authority.Date of entry into force: Unknown

Wall-luminaires "Sevinc Aydinlatma" 1. Double wall-bracket; type/model: 2065/2.A (type version: 2060/2.A).2. Single wall-bracket. 2080/1.A (type versions: 2065/1.A; 2060/1.A; 2005/1.A).