Electric shock

0619/05

imageimageimage
Case number
0619/05
Category
Lighting chains
Audience
Consumer
Notifying country
🇭🇺 Hungary
Country of origin
🇨🇳 China
Published
2005-12-02

⚠️ Risk

Flexible, single-insulated wire is applied between the plug and the flashing unit. The cross-sectional area of the wire is <0,1 mm2.Flexible, single-insulated wire is applied between the flashing unit and the lamps insulated by heat shrink tube, soldered into the wire. The cross-sectional area of the wire is <0,1 mm2.The bushing of the flashing unit is not rounded off. The flexible wires soldered to the bushing are not supplied with conductor relief. The single-core wire comes off the soldering under force of 23,4N.The plug is not of standardized type.

Measures

Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Distribution of a product prohibited by the authority.Date of entry into force: Unknown

Lighting chain labelled on the package as follows: "For Happy Christmas 60L, 80L, 100L, 140L with 100 pieces of not replaceable miniature lamps and with a flashing unit of 8 functions.Type/number of model: 60L, 80L, 100L, 140.