Manual illuminator
"Bottari"
- Case number
- 0321/06
- Category
- Lighting equipment
- Type / Model
- Unknown.
- Audience
- Consumer
- Notifying country
- 🇱🇹 Lithuania
- Country of origin
- Unknown
- Published
- 2006-06-16
⚠️ Risk
The product poses a risk of electric shock because it suffers from insufficient fastening of the cable, the cross-section of main cable is smaller then required (0,43mm2), the product did not pass the bent test (all cable conductors broke down) and the marking does not comply with the requirements (wrong voltage indication, essential symbols are missing).The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.
Measures
Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Withdrawal from the market ordered by the authority.Date of entry into force: Unknown