Electric shock, Fire

0641/06

image
Case number
0641/06
Category
Electrical appliances and equipment
Audience
Consumer
Notifying country
🇨🇿 Czech Republic
Country of origin
🇨🇳 China
Published
2006-10-06

⚠️ Risk

This product poses a risk of electric shock and fire because:- the equipment does not meet the protection requirements in a single fault condition (dangerous live parts);- the measured creepage distances do not meet the requirements on double insulation; - the minimum reinforced insulation which is required between the enclosure and live parts is not provided;- the protection against electric shock is not secured at the test probes; - after the testing the excessive prolongation of the cable occurred and the insulation moved in the terminal by more than 2 mm.-marking - the pictures (pictograms) are not in compliance with the standard. This product does not comply with the Low Voltage Directive and the LVD standards.

Measures

Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Sales ban ordered by the authority. Date of entry into force: Unknown

Digital multimeter "SOLID".Type/model: RE830A; EAN 8 595092 106072.Description: Electronic measuring equipment in a yellow enclosure (Class of protection II) supplied with two measuring probes for the measurement of CAT II and a digital display 31/2 dig., A safe range use: direct-voltage up to 1000V, direct-current up to 200mA, alternating-voltage up to 750V.