Electric shock

AC adaptor for TFT television/monitor “Denver” (television itself is not affected)

AC adaptor for TFT television/monitor “Denver” (television itself is not affected)
Case number
0753/06
Category
Electrical appliances and equipment
Type / Model
FJ-SW1210X
Barcode
5 700751 005299
Audience
Consumer
Notifying country
🇫🇮 Finland
Country of origin
Unknown
Published
2006-11-24

⚠️ Risk

The product poses a serious risk of electric shock because: - the insulation between the parts connected to the mains (primary circuit) and parts that can be touched by the user (secondary circuit) is not sufficient. In particular: - creepage distances and clearances in the mains transformer between the primary windings and secondary windings are less than 5mm/4 mm (measured a minimum of 0.4 mm); - the secondary circuit is accessible through the terminals. The product does not comply with the Low Voltage Directive and the relevant European standard EN 60065.

Measures

Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Withdrawal from the market and recall from consumers ordered by the authority.Date of entry into force: Unknown