Electric shock

Lighting chain.

Unknown.
Lighting chain.
Case number
0073/07
Category
Lighting equipment
Type / Model
Cocoon 35 NF.
Audience
Consumer
Notifying country
🇪🇸 Spain
Country of origin
Thailand
Published
2007-01-26

⚠️ Risk

The product poses a serious risk of electric shock because:- the wire does not meet the type-cable specifications of the standard,- the conductor section area is 0.18 mm² which is less than the required 50 mm², - the wire does not pass the tensile test,– the length of the wire between the plug and the first lamp-holder is 1 metre which is less than the required 1.50 metres,- the product does not pass the pressure test on resistance to heat, fire and tracking for each ball,- there are no safety marks or safety instructions.The product does not comply with the Low Voltage Directive

Measures

Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Import of the product rejected by the customs authorities.Date of entry into force: Unknown