Electric shock

Lighting chain

Unknown
Lighting chain
Case number
0020/07
Category
Lighting equipment
Type / Model
Rose 20 NP-L
Audience
Consumer
Notifying country
🇪🇸 Spain
Country of origin
Thailand
Published
2007-01-13

⚠️ Risk

This product poses a serious risk of electric shock because:- the characteristics of the chain’s cable are lower than specified in the standard;- the nominal cross-section of the conductors is 0,36 mm², which is less than the 50 mm² required by the standard;- the length of the wire between the plug and the first bulb holder is 1,00 m, which is less than the 1,50 m required by the standard;- there are no safety markings and instructions.This product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.

Measures

Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Import rejected by the customs authoritiesDate of entry into force: Unknown