Electric shock

Lighting chain

Unknown
Lighting chain
Case number
0030/07
Category
Lighting equipment
Type / Model
Cocoon NF Tree Light
Audience
Consumer
Notifying country
🇪🇸 Spain
Country of origin
Thailand
Published
2007-01-13

⚠️ Risk

This product poses a serious risk of electric shock due to the following non-compliances with the relevant European standard EN 60598:- the wire in the chain has inferior characteristics to those specified in the standard;- the nominal cross-section of the conductors is 0,06 mm², which is less than the required 50 mm²;- the wire failed the traction test;- the required safety markings and instructions are missing.The product does not comply with the Low Voltage Directive.

Measures

Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Import of the product has been rejected by the customs authoritiesDate of entry into force: Unknown