Electric shock, Fire

Table lamp (TOMI)

Szarvas
Table lamp (TOMI)Table lamp (TOMI)
Case number
0354/07
Category
Lighting equipment
Type / Model
DSL-010 B-65
Audience
Consumer
Notifying country
🇭🇺 Hungary
Country of origin
🇨🇳 China
Published
2007-04-20

⚠️ Risk

This product poses a risk of electric shock because:- the insulation of the internal wiring may get damaged due to the presence of burry metal edges;- the protecting plastic tubes are not fixed, thus they can move at the lamp shade and the basic insulated wires can get into contact with accessible metal cover;- the cross section area is less than required. This product poses a risk of fire because the luminaire tipped over on a standard slope which may entail the overheating of the supporting surface.This product does not comply with the Low Voltage Directive and the relevant European standards.

Measures

Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Withdrawal from the market, recall from consumers and information to consumers ordered by the authoritiesDate of entry into force: Unknown