Electric soldering iron
PLASTENA
- Case number
- 0544/087
- Category
- Electrical appliances and equipment
- Type / Model
- V362 PROFESSIONAL, Bar code: 8014132084069
- Audience
- Consumer
- Notifying country
- 🇪🇸 Spain
- Country of origin
- Unknown
- Published
- 2008-05-16
⚠️ Risk
The product poses a risk of electric shock because:- it does not have instructions for use, operation or cleaning, - it is possible to access metal parts which are only separated from the live parts by functional insulation,- the insulation did not withstand the voltage test,- the insulation failed the electric strength test, as there are insulation sleeves which are not securely positioned,- the dimensions of the plug are different from those specified in the standard,- the supply cable section is 0.36 mm², which is less than the 0.50 mm² required by the standard, and there is no device to anchor the supply cable to protect it against pulling and twisting,- the supply conductors are not fixed by terminals and the connection is made by twisting the conductors, without any other form of support,- the clearances and creepage distances between live parts and accessible metal parts are less than those laid down in the standard.The product does not comply with the Low Voltage Directive and the relevant European standard EN 60335.
Measures
Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Withdrawal from the market ordered by the authorities.Date of entry into force: Unknown