Electric shock, Fire

Lighting chain - Fairy lights with 100 lamps

PHU
Lighting chain - Fairy lights with 100 lampsLighting chain - Fairy lights with 100 lamps
Case number
1423/08
Category
Lighting chains
Type / Model
EL100MT, EL100MX
Audience
Consumer
Notifying country
🇩🇪 Germany
Country of origin
Unknown
Published
2008-12-05

⚠️ Risk

The existing conductor cross section is about 0.15 mm², the required cross section is 0.5 mm², thus overload is possible, as the function is that of an extension cord with accompanying luminaire. The conductor insulation does not fulfill the requirements for double insulation according to EN 60598-2-20, thereby it can be easily damaged.

Measures

Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Withdrawal from the market ordered by the authorities.Date of entry into force: Unknown

Indoor chain of lights with 100 little jack lamps, extendable, with a Euro plug 230 V, 50 Hz, max. 35 W