Charger
Unknown
- Case number
- 0766/12
- Category
- Electrical appliances and equipment
- Audience
- Consumer
- Notifying country
- 🇬🇧 United Kingdom
- Country of origin
- 🇨🇳 China
- Published
- 2012-05-25
⚠️ Risk
The product poses a risk of electric shock because: · The wires to the live mains plugs pins are not secured independently of their soldered connections. · Creepage distances are insufficient between “live” and “accessible” printed tracks. · The insulation between the primary and secondary windings of the transformer is not equivalent to reinforced insulation.· Creepage distance of the windings is not sufficient. · The pins of the plug are too short.The product does not comply with the Low Voltage Directive (LVD) and the relevant European standard EN 60950.
Measures
Type of economic operator taking notified measure(s): OtherCategory of measure(s): Withdrawal of the product from the marketDate of entry into force: Unknown