Electric shock

Lighting chain

Lighting chainLighting chainLighting chain
Case number
A12/0433/13
Category
Lighting chains
Type / Model
WT-2F30/1.5-1~20-a2 (on the product),WT-2K 30/1.5-1~80-a2 (on the packaging)
Batch
6 822120 123032
Audience
Consumer
Notifying country
🇭🇺 Hungary
Country of origin
🇨🇳 China
Published
2013-04-12

⚠️ Risk

null The product poses a risk of electric shock because:·        the lid of the control unit can be detached without tools and the basic insulated wire parts become accessible,·        the wire ends soldered to terminals of the control unit are not adequately protected against pulling and twisting,·        the accessible wires have only basic insulation and are in contact with sharp edges of the control unit,·        the electrical insulation of the light sources is not adequate,·        it is not protected against moisture, yet it is recommended for outdoor use.The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.

Lighting chain in the form of 5-pointed stars on a metal frame.