Burns, Electric shock

Lighting chain

Best
Lighting chainLighting chainLighting chain
Case number
A12/0170/14
Category
Lighting chains
Type / Model
Model: YS-100L-LED
Batch
Unknown
Audience
Consumer
Notifying country
🇭🇺 Hungary
Country of origin
Unknown
Published
2014-01-31

⚠️ Risk

null - The cross sectional area of the external and internal wires is too small and they could overheat.- The wire ends soldered to terminals of the control unit and the LEDs are not adequately protected against pulling and twisting.- The accessible basic insulated wires can come into contact with sharp edges of the control unit and could be damaged.- The socket of the extension lead enables single-pole insertion of a plug with the free remaining live pin accessible- The product is not protected against moisture but is recommended for outdoor use. The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.

Measures

Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Withdrawal of the product from the marketDate of entry into force: UnknownType of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Recall of the product from end usersDate of entry into force: 06/12/2013

Lighting chain with 100 white LED lamps and control unit.Packaging: transparent plastic box
Toxic DB: