Lighting chain
Unknown
- Case number
- A12/0746/14
- Category
- Lighting chains
- Type / Model
- WZ636C
- Batch
- 6 901058 010000
- Audience
- Consumer
- Notifying country
- 🇭🇺 Hungary
- Country of origin
- Unknown
- Published
- 2014-05-30
⚠️ Risk
null The cross sectional area of the external and internal wires is too small and the wires could overheat. The wire ends soldered to the terminals of the flashing unit and the LEDs are not adequately protected against pulling and twisting. The accessible basic insulated wires can come into contact with sharp edges of the flashing switch and control unit. The product does not comply with the requirements of the Low Voltage Directive and the relevant European standard EN 60598.
Measures
Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Withdrawal of the product from the marketDate of entry into force: UnknownType of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Recall of the product from end usersDate of entry into force: 28/03/2014