Burns, Electric shock

Lighting chain

Unknown
Lighting chainLighting chainLighting chain
Case number
A12/0729/14
Category
Lighting chains
Type / Model
YS-180L-LED
Batch
Unknown
Audience
Consumer
Notifying country
🇭🇺 Hungary
Country of origin
Unknown
Published
2014-05-23

⚠️ Risk

null The cross-sectional area of the external and internal wires is too small and the wires could overheat. The wire ends soldered to the terminals of the flashing unit and the LEDs are not adequately protected against pulling and twisting. The accessible basic insulated wires can come into contact with sharp edges of the flashing switch and control unit. The product is not protected against moisture but is recommended for outdoor use. The extension socket allows the single-pole insertion of a plug with the free remaining live pin accessible.The product does not comply with the requirements of the Low Voltage Directive and the relevant European standard EN 60598.

Measures

Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Withdrawal of the product from the marketDate of entry into force: UnknownType of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Recall of the product from end usersDate of entry into force: 26/03/2014

Lighting chain with 180 white or purple LED lamps. There is a socket outlet that allows the connection of another lighting chain. Packaging: transparent plastic box with a label.