Lighting chain
Ante


- Case number
- A12/1157/14
- Category
- Lighting chains
- Type / Model
- DCH
- Batch
- 599048655134
- Audience
- Consumer
- Notifying country
- 🇸🇰 Slovakia
- Country of origin
- 🇨🇳 China
- Published
- 2014-08-01
⚠️ Risk
null The product poses a risk of electric shock and fire because the mechanical strength of the flashing unit is not sufficient and the user may have access to live parts. The insulation material of the flashing unit is flammable and the cross-sectional area of the external and internal wires is less than the minimum required, thus, they could overheat and the product could easily catch fire.The product does not comply with the requirements of the Low Voltage Directive and the relevant European standard EN 60598.
Measures
Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Ban on the marketing of the product and any accompanying measuresDate of entry into force: 03/01/2014Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Withdrawal of the product from the marketDate of entry into force: 03/01/2014Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Recall of the product from end usersDate of entry into force: 03/01/2014