Carbon monoxide detector
CMI


- Case number
- A12/1942/14
- Category
- Construction products
- Type / Model
- Model no: JB-C686L - 345691
- Batch
- 4007873456916Batch: PO 480881 L 2013
- Audience
- Consumer
- Notifying country
- 🇵🇱 Poland
- Country of origin
- 🇨🇳 China
- Published
- 2014-12-12
⚠️ Risk
null The detector is not sufficiently sensitive to CO. The alarm does not promptly switch on, the people who are in the room may get intoxicated and asphyxiation may occur.The product does not comply with the relevant European standard EN 50291.
Measures
Type of economic operator taking notified measure(s): OtherCategory of measure(s): Withdrawal of the product from the marketDate of entry into force: UnknownType of economic operator taking notified measure(s): OtherCategory of measure(s): Recall of the product from end usersDate of entry into force: Unknown