Floodlight
Lexxa


- Case number
- A12/0564/15
- Category
- Lighting equipment
- Type / Model
- Charger: KJ-TCA388 , Light: 433 610 BL-RE-TG-10W-01
- Batch
- 6 430038 496133
- Audience
- Consumer
- Notifying country
- 🇫🇮 Finland
- Country of origin
- 🇨🇳 China
- Published
- 2015-05-01
⚠️ Risk
null The insulation of the transformer in the charger is not sufficient. The clearance /creepage distances between the primary and secondary windings of the transformer are not sufficient.The product does not comply with the requirements of the Low Voltage Directive and the relevant European standard EN 61558.
Measures
Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Withdrawal of the product from the marketDate of entry into force: 09/02/2015Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Recall of the product from end usersDate of entry into force: 09/02/2015