Injuries

Concrete mixer pump

Cifa
Concrete mixer pumpConcrete mixer pump
Case number
A12/1191/16
Category
Machinery
Type / Model
MK28.4.L 4Z/115RH, manufactured in 2007
Batch
serial number: 12199
Audience
Professional
Notifying country
🇵🇱 Poland
Country of origin
🇮🇹 Italy
Published
2016-09-30

⚠️ Risk

null The strength of the outrigger pillar is insufficient due to a fault of the structure material. During pouring of concrete, when the boom of the pump is in its maximum horizontal position, the construction breaks and hits workers who are present in the working zone of the boom. The product does not comply with the requirements of the Machinery Directive.Four fatal accidents were reported.

Measures

Type of economic operator taking notified measure(s): OtherCategory of measure(s): Recall of the product from end usersDate of entry into force: Unknown

Product is installed on the chassis of the truck and intended for mixing and dispensing of concrete.