Concrete mixer pump
Cifa

- Case number
- A12/1191/16
- Category
- Machinery
- Type / Model
- MK28.4.L 4Z/115RH, manufactured in 2007
- Batch
- serial number: 12199
- Audience
- Professional
- Notifying country
- 🇵🇱 Poland
- Country of origin
- 🇮🇹 Italy
- Published
- 2016-09-30
⚠️ Risk
null The strength of the outrigger pillar is insufficient due to a fault of the structure material. During pouring of concrete, when the boom of the pump is in its maximum horizontal position, the construction breaks and hits workers who are present in the working zone of the boom. The product does not comply with the requirements of the Machinery Directive.Four fatal accidents were reported.
Measures
Type of economic operator taking notified measure(s): OtherCategory of measure(s): Recall of the product from end usersDate of entry into force: Unknown