Asphyxiation

CO detector

König
CO detector
Case number
A12/1750/16
Category
Construction products
Type / Model
SAS-CA200
Batch
5412810236510
Audience
Consumer
Notifying country
🇳🇱 Netherlands
Country of origin
🇨🇳 China
Published
2016-12-23

⚠️ Risk

null In case of a defect in the sensor, or in case the sensor is short-circuited or disconnected, the CO detector does not produce a fault signal. Also, if the detector is exposed to high humidity it does not work correctly.The product does not comply with the relevant European standard EN 50291.

Measures

Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Withdrawal of the product from the marketDate of entry into force: 26/10/2016Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Ban on the marketing of the product and any accompanying measuresDate of entry into force: 26/10/2016Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Recall of the product from end usersDate of entry into force: 26/10/2016

White CO detector packed in a cardboard box.