LED floodlight
Unknown


- Case number
- A12/1706/16
- Category
- Lighting equipment
- Audience
- Consumer
- Notifying country
- 🇭🇺 Hungary
- Country of origin
- Unknown
- Published
- 2016-12-23
⚠️ Risk
null The earth conductor is not connected to accessible live metal parts. The cables are not properly secured against pulling and twisting and the wire ends can be pulled out easily. The PVC cables do not protect sufficiently against water penetration. As a result of these defects, the user could touch live parts during normal use.The product does not comply with the requirements of the Low Voltage Directive and the relevant European standard EN 60598.
Measures
Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Withdrawal of the product from the marketDate of entry into force: UnknownType of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Recall of the product from end usersDate of entry into force: 07/06/2016