Electric shock, Fire

Light

Asa
LightLight
Case number
A12/1424/16
Category
Lighting equipment
Type / Model
REF: 10545
Batch
5 995858 105456
Audience
Consumer
Notifying country
🇭🇺 Hungary
Country of origin
🇨🇳 China
Published
2016-11-04

⚠️ Risk

null The cross-sectional area of the external and internal wires is too small and the wires could overheat. Live parts can be touched when the flat plug is plugged into the mains since the dimensions of the flat plug are not suitable. The wire ends soldered to the terminals of the rectifier unit are not adequately protected against pulling and twisting. As a consequence, the cable could become loose causing accessible parts to become live.The product does not comply with the requirements of the Low Voltage Directive and the relevant European standard EN 60598.

Measures

Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Withdrawal of the product from the marketDate of entry into force: UnknownType of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Recall of the product from end usersDate of entry into force: 20/09/2016

Mains operated light with 3 rotating LEDs and 48 fixed LEDs (red, blue and green). Packaging: colourful cardboard box.