Electric shock, Fire

Lighting chain

Best
Lighting chainLighting chainLighting chainLighting chain
Case number
A12/1574/16
Category
Lighting chains
Type / Model
ITEM NO.: YS-240L-R
Audience
Consumer
Notifying country
🇭🇺 Hungary
Country of origin
🇨🇳 China
Published
2016-12-02

⚠️ Risk

null The cross-sectional area of the external and internal wires is too small and they can overheat. The wire ends are not adequately protected against pulling and twisting. The accessible wires have only basic insulation and are in contact with sharp edges. The cover of control unit is not properly fixed. The electrical insulation is not sufficient. The product is recommended also for outdoor use but is not protected against moisture. The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.

Measures

Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Withdrawal of the product from the marketDate of entry into force: 08/06/2016Type of economic operator taking notified measure(s): ImporterCategory of measure(s): Destruction of the productDate of entry into force: Unknown

The lighting chain is supplied in a colourful cardboard box.