Burns, Electric shock, Fire

0051/06

obrázekobrázek
Číslo případu
0051/06
Kategorie
Lighting equipment
Cílová skupina
Consumer
Notifikující země
🇭🇺 Maďarsko
Země původu
🇨🇳 Čína
Zveřejněno
2006-02-10

⚠️ Riziko

The lamps were not provided with the SELV transformer (reducing mains supply voltage to extra low voltage). During the thermal test the highest measured temperature of the accessible parts (including the incandescent lamp) was 84,3°C (dolphin) and 175,2°C (butterfly). The glasses covering the incandescent lamp in the dolphin-formed luminaire broke due to the impact of 0,7 Nm force and the hot incandescent lamp became accessible by the small test finger. These products do not comply with the LVD Directive and the European Standards.

Opatření

Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Recall and prohibition of selling ordered by authority.Date of entry into force: Unknown

Desk lamps "Artistar ALF98" 1. Dolphin-formed; type/model: LPT-4009N/1 2. Butterfly-formed; type/model: LT-1204D.