Electric shock

0618/05

obrázekobrázek
Číslo případu
0618/05
Kategorie
Lighting chains
Cílová skupina
Consumer
Notifikující země
🇭🇺 Maďarsko
Země původu
🇨🇳 Čína
Zveřejněno
2005-12-02

⚠️ Riziko

Flexible, single-insulated wire is applied between the plug and the flashing unit. The cross-sectional area of the wire is <0,1 mm2.Flexible, single-insulated wire is applied between the flashing unit and the lamps insulated by heat shrink tube, soldered into the wire. The cross-sectional area of the wire is <0,1 mm2. The bushing of the flashing unit is not rounded off. The flexible wires soldered to the bushing are not supplied with conductor relief. The single-core wire comes off the soldering under force of 10,2N. The plug is not of standardized type.

Opatření

Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Distribution of a product prohibited by the authority.Date of entry into force: Unknown

Lighting chain labelled on the package as follows: "Decorator Micro Light Set" with 140 pieces of not replaceable miniature lamps and with a flashing unit of 8 functions.