0620/05



- Číslo případu
- 0620/05
- Kategorie
- Lighting chains
- Cílová skupina
- Consumer
- Notifikující země
- 🇭🇺 Maďarsko
- Země původu
- 🇨🇳 Čína
- Zveřejněno
- 2005-12-02
⚠️ Riziko
Flexible, single-insulated wire is applied between the plug and the flashing unit. The cross-sectional area of the wire is <0,1 mm2. Flexible, single-insulated wire is applied between the flashing unit and the lamps insulated by heat shrink tube, soldered into the wire. The bushing of the flashing unit is not rounded off. The flexible wires soldered to the bushing are not supplied with conductor relief. The single-core wire comes off the soldering under force of 15,2N. The plug is not of standardized type.
Opatření
Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Distribution of a product prohibited by the authority.Date of entry into force: Unknown