0714/05


- Číslo případu
- 0714/05
- Kategorie
- Electrical appliances and equipment
- Cílová skupina
- Consumer
- Notifikující země
- 🇬🇷 Řecko
- Země původu
- 🇨🇳 Čína
- Zveřejněno
- 2006-01-06
⚠️ Riziko
The conductors of the supply cord have nominal cross sectional area 0,75mm2, whereas the less permitted cross sectional area is 1mm2.The withholding hook of the sample does not protect the conductors from twisting. The withholding hook of the supply cord is not sufficient. The length of the earth conductor is such that it does not ensure that the earth conductor will disconnect after the disconnection of the live conductors, in case the supply cord gets out of the withholding hook. The screws inside the insulating material of the sample cause damage to the insulating materialThis product does not comply with the LVD Directive and the European Standard.
Opatření
Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Withdrawal from the market ordered by the authority.Date of entry into force: Unknown