Electric shock

0112/06

obrázek
Číslo případu
0112/06
Kategorie
Electrical appliances and equipment
Cílová skupina
Consumer
Notifikující země
🇫🇮 Finsko
Země původu
Unknown
Zveřejněno
2006-03-10

⚠️ Riziko

Creepage distances and clearances in the mains transformer between the primary windings and secondary windings / between the primary windings and output winding wires of the secondary windings / between the secondary windings and output winding wires of the primary windings are less than 4 mm; measured a minimum of 0.2 mm. The secondary circuit is accessible through the terminals. The windings are positioned concentrically on a single coil former and wounded on the edge of the coil former. This product does not comply with the LVD Directive and the European Standards.

Opatření

Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Recall from consumers ordered by the authority.Date of entry into force: Unknown

Power supply unit for portable DVD player.Type/model: FJ-SW2545XY.