0112/06

- Číslo případu
- 0112/06
- Kategorie
- Electrical appliances and equipment
- Cílová skupina
- Consumer
- Notifikující země
- 🇫🇮 Finsko
- Země původu
- Unknown
- Zveřejněno
- 2006-03-10
⚠️ Riziko
Creepage distances and clearances in the mains transformer between the primary windings and secondary windings / between the primary windings and output winding wires of the secondary windings / between the secondary windings and output winding wires of the primary windings are less than 4 mm; measured a minimum of 0.2 mm. The secondary circuit is accessible through the terminals. The windings are positioned concentrically on a single coil former and wounded on the edge of the coil former. This product does not comply with the LVD Directive and the European Standards.
Opatření
Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Recall from consumers ordered by the authority.Date of entry into force: Unknown