Electric shock, Injuries

0442/06

obrázekobrázek
Číslo případu
0442/06
Kategorie
Lighting equipment
Cílová skupina
Consumer
Notifikující země
🇨🇿 Česko
Země původu
Unknown
Zveřejněno
2006-07-21

⚠️ Riziko

The product poses a risk of electric shock and injury because:- Insufficient resistance of the polystyrene cover of the hole in the base can not prevent the consumer from touching the live parts.- The requirements for accessible internal wiring on double/reinforced insulation are not met.- The internal wiring is not protected against abrasion in the sharp edges of opening.- The insulation lining in a lampholder is not in compliance with the safety requirements for replacement of the lamp.- The stability of the luminaire is inadequate.- The supply cord is secured by knotting the cord.This product does not comply with the Low Voltage Directive and the relevant European Standard EN 60598.

Opatření

Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Sales ban ordered by the authority. Date of entry into force: Unknown

Table lamp with a porcelain base with a motif of blue dolphins and with an ultrasonic remote control.Type/number of model: HD-2002-1.