0466/06

- Číslo případu
- 0466/06
- Kategorie
- Electrical appliances and equipment
- Čárový kód
- 8711295 422300
- Cílová skupina
- Consumer
- Notifikující země
- 🇳🇱 Nizozemsko
- Země původu
- 🇨🇳 Čína
- Zveřejněno
- 2006-08-04
⚠️ Riziko
This product poses a risk of electric shock because:- live parts with a dangerous charge (68,0VACpeak) are accessible with the test finger, - charge of accessible live parts (52,9μC) exceeds limit indicated in the standard (45μC),- leakage current of 126 mApeak is too high (0,25mApeak is required by the standard) and is accessible.This product does not comply with the Low Voltage Directive and LVD Standard.
Opatření
Type of economic operator taking notified measure(s): OtherCategory of measure(s): Placing of the product on the market voluntarily suspended. Voluntary recall from consumers.Date of entry into force: Unknown