Electric shock, Fire

0540/06

obrázek
Číslo případu
0540/06
Kategorie
Electrical appliances and equipment
Cílová skupina
Consumer
Notifikující země
🇫🇮 Finsko
Země původu
Unknown
Zveřejněno
2006-08-25

⚠️ Riziko

The product poses a risk of electric shock and fire because:- temperature controller and thermal limit control the same contactor which is not allowed since thermal limit does not work if the contacts of the contactor will weld to each other;- opening of the switch (contactor) is approximately 0.5 mm whereas the requirement is 3.0 mm;- locking hole is missing from the terminal part of the earthing terminal;- connection diagram is missing from the connection space of the product;- fixing devices needed to fix the product on the wall are missing;- instructions for use and installations and markings are unclear, defective and/or contradictory.This product does not comply with the Low Voltage Directive and the European Standard EN 60335.

Opatření

Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Recall from consumers ordered by the authority.Date of entry into force: Unknown

Sauna heating appliance “TM-TOOLS”Type/model: Type: PSAU-60NS, EAN: 6 405086 002506.