0558/06

- Číslo případu
- 0558/06
- Kategorie
- Electrical appliances and equipment
- Typ / Model
- Classic 30/112
- Cílová skupina
- Consumer
- Notifikující země
- 🇫🇮 Finsko
- Země původu
- 🇺🇸 USA
- Zveřejněno
- 2006-09-01
⚠️ Riziko
The product poses a risk of electric shock because the electrical insulation in the mains transformer between the output wire of secondary winding and the primary winding is not sufficient. The output wire of secondary winding is connected over the primary winding and they touch each other. The secondary circuit is accessible through the terminals.This product does not comply with the Low Voltage Directive and the European Standard EN 60065.
Opatření
Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Recall from consumers ordered by the authority.Date of entry into force: Unknown