Electric shock, Fire

0605/06

obrázek
Číslo případu
0605/06
Kategorie
Electrical appliances and equipment
Typ / Model
GTM-116
Cílová skupina
Consumer
Notifikující země
🇬🇷 Řecko
Země původu
🇨🇳 Čína
Zveřejněno
2006-09-29

⚠️ Riziko

The product was examined according to the requirements of the Low voltage Directive 73/23/EEC and has been found in non-compliance with the requirements of the applicable standards because:a) The rise of temperature at inner wiring was 129 K, with upper limit 50 K (risk of fire)b) During the test the resistant melted and touched the plastic base of the appliance (risk of fire)c) The earth cable conduit is shorter than the current ones (risk of electric shock)

Opatření

Type of economic operator taking notified measure(s): OtherCategory of measure(s): Voluntary actions taken by the importer: withdrawal from the market, recall from consumers and information to consumers.Date of entry into force: Unknown

Coffee maker "PERLA"