0606/06

- Číslo případu
- 0606/06
- Kategorie
- Electrical appliances and equipment
- Cílová skupina
- Consumer
- Notifikující země
- 🇬🇧 Spojené království
- Země původu
- 🇨🇳 Čína
- Zveřejněno
- 2006-09-29
⚠️ Riziko
The product poses a risk of electric shock because: - the luminaire has inadequate protection against electric shock; the wiring protected by single layer insulation is in contact with accessible components;- the luminaire failed the electric strength test; the insulation broke down when a test voltage of 2100 V was applied; although it should withstand 3710 V for 1 minute;- the supply cord is unsuitable as it had inadequately sized conductors; - the lamp connections are glued into position so the lamp cannot be safely and easily replaced;- the markings and instructions are insufficient to allow safe usage/maintenance.The product does not comply with the Low Voltage Directive and the relevant European standard 60598.
Opatření
Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Confiscation of the products and press release issued by the authority.Date of entry into force: Unknown