AC adaptor for TFT television/monitor “Denver” (television itself is not affected)

- Číslo případu
- 0753/06
- Kategorie
- Electrical appliances and equipment
- Typ / Model
- FJ-SW1210X
- Čárový kód
- 5 700751 005299
- Cílová skupina
- Consumer
- Notifikující země
- 🇫🇮 Finsko
- Země původu
- Unknown
- Zveřejněno
- 2006-11-24
⚠️ Riziko
The product poses a serious risk of electric shock because: - the insulation between the parts connected to the mains (primary circuit) and parts that can be touched by the user (secondary circuit) is not sufficient. In particular: - creepage distances and clearances in the mains transformer between the primary windings and secondary windings are less than 5mm/4 mm (measured a minimum of 0.4 mm); - the secondary circuit is accessible through the terminals. The product does not comply with the Low Voltage Directive and the relevant European standard EN 60065.
Opatření
Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Withdrawal from the market and recall from consumers ordered by the authority.Date of entry into force: Unknown