Magic Night Light


- Číslo případu
- 0825/06
- Kategorie
- Lighting equipment
- Cílová skupina
- Consumer
- Notifikující země
- 🇬🇧 Spojené království
- Země původu
- Israel
- Zveřejněno
- 2006-12-15
⚠️ Riziko
This product poses a serious risk of electric shock because there is insufficient distance between the live and neutral pins and the plug periphery. In addition, the fuse link is below standard dimensional requirements. To ensure effective operation of the fuse link, standard BS 1363 requires the fuse link to be mounted between the line termination and corresponding plug pin. In this case, the fuse link is mounted after the lamp and the switch and actually connected to the neutral termination and the corresponding plug pin. Therefore, in the event of a fault within the product the fuse link may not operate thereby removing the intended over-current protection, which could result in an electric shock.This product does not comply with the national standard BS 1363
Opatření
Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Product will be destroyed by the retailerDate of entry into force: UnknownType of economic operator taking notified measure(s): OtherCategory of measure(s): Product will be destroyed by the retailerDate of entry into force: Unknown