Electric shock

Power supply units

Prescott
Power supply unitsPower supply units
Číslo případu
0271/07
Kategorie
Electrical appliances and equipment
Typ / Model
LC-D500EXP
Cílová skupina
Consumer
Notifikující země
🇫🇮 Finsko
Země původu
Unknown
Zveřejněno
2007-03-23

⚠️ Riziko

This product poses a risk of electric shock because - there is not sufficient electrical insulation between the primary circuit connected to the mains and the secondary circuit that can be touched. The secondary circuit can be touched via the product connected to the output of the power supply unit. In particular:- clearances/creepage distances in transformer T2 between the primary and the secondary windings are less than 4 mm/5 mm; a minimum of 0.2 mm between the primary winding and the output wires of the secondary winding and 0.5mm between the secondary winding and the output wires of the primary winding are measured; on the output wires there are not insulation tubes;- clearances/creepage distances in transformer T3 between the primary and the secondary windings are less than 4 mm/5 mm; a minimum of 0.3 mm between the primary winding and the output wires of the secondary winding and 0.3 mm between the secondary winding and the output wires of the primary winding are measured; on the output wires there are not insulation tubes.This product does not comply with the Low Voltage Directive and the relevant European standard EN 60950.

Opatření

Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Recall from consumers ordered by the authoritiesDate of entry into force: Unknown