Electric shock

Halogen room heater

Extreme Heat
Halogen room heater
Číslo případu
0460/07
Kategorie
Electrical appliances and equipment
Typ / Model
XT-120B1S
Čárový kód
Bar code 6912345667890
Cílová skupina
Consumer
Notifikující země
🇬🇧 Spojené království
Země původu
🇨🇳 Čína
Zveřejněno
2007-05-25

⚠️ Riziko

This product poses a risk of electric shock because:- the top of the heater is a class 11 construction. The wiring to the switches has been routed too close to the grille at the top of the heater giving inadequate protection against accidental contact with basic insulation;- the front cover does not withstand the pull test and became unlatched at a force of 21.7N. This allowed access to internal wiring and terminals.This product does not comply with the Low Voltage Directive.

Opatření

Type of economic operator taking notified measure(s): OtherCategory of measure(s): Voluntary recall of the product from consumersDate of entry into force: Unknown

Grey Halogen room heater 1200w marked 'Extreme heat', packed in blue and white box