Starting cables
O.K.

- Číslo případu
- 0932/07
- Kategorie
- Electrical appliances and equipment
- Typ / Model
- 150A, code: AL-AG0003, XX1238242, EAN code: 9004181009235
- Cílová skupina
- Consumer
- Notifikující země
- 🇸🇰 Slovensko
- Země původu
- 🇨🇳 Čína
- Zveřejněno
- 2007-09-21
⚠️ Riziko
This product poses a serious risk of fire because at simulation of thermal overload of cable, allowed temperature during the starting impulse is 135 ºC. When testing, during the one starting impulse (max. 150A, 15s) the temperature of conductor reached 314 ºC, during the second starting impulse (max. 150A, 30s) the temperature of conductor reached more than 400 ºC. After the tests were finished, the insulation got on fire and conductors burned down.
Opatření
Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Sales ban, withdrawal from the market and recall from consumers ordered by the authoritiesDate of entry into force: Unknown