Starting cables
Car Commerce
- Číslo případu
- 0973/07
- Kategorie
- Electrical appliances and equipment
- Typ / Model
- 400A, 2,5m, Art. 42143, code: 0538
- Cílová skupina
- Consumer
- Notifikující země
- 🇸🇰 Slovensko
- Země původu
- 🇨🇳 Čína
- Zveřejněno
- 2007-09-28
⚠️ Riziko
This product poses a serious risk of fire because:- at simulation of thermal overload of cable, allowed temperature during the starting impulse is 135 ºC. When testing, during the one starting impulse (max. 400A, 15s) the temperature of conductor reached 357 ºC, during the second starting impulse (max. 400A, 30s) the temperature of conductor reached more than 400 ºC,- after tests have finished, the insulation got on fire and conductors burned down.
Opatření
Type of economic operator taking notified measure(s): OtherCategory of measure(s): Voluntary withdrawal from the market and information to consumers by the distributorDate of entry into force: Unknown