Electric shock, Fire

Electric pad

SPESA INTELIGENT
Electric padElectric pad
Číslo případu
0464/08
Kategorie
Electrical appliances and equipment
Typ / Model
Batch code: 90806.01 7 TYD001/BL001
Cílová skupina
Consumer
Notifikující země
🇸🇮 Slovinsko
Země původu
🇨🇳 Čína
Zveřejněno
2008-05-02

⚠️ Riziko

The product poses a risk of electric shock because :- the creepage distances of reinforced insulation is insufficient: distance between live parts and accessible surface is 2.2 mm - it should not be less than 8 mm, - creepage distance of functional insulation is insufficient: distances between live parts are 1.8 mm, 1.86 mm, 0.95 mm - they should not be less than 3.2 mm. The product poses a risk of fire because of:- insufficient resistance to heat and fire, - absence of required markings.The product does not comply with the Low Voltage Directive and the relevant European standard EN 60335.

Opatření

Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Withdrawal from the market ordered by the authorities.Date of entry into force: Unknown

Unknown