Injuries

Carabiner

KONG
Carabiner
Číslo případu
0477/08
Kategorie
Protective equipment
Typ / Model
KN<>22◊8∞ 7 Batch code : 050588 05
Cílová skupina
Consumer
Notifikující země
🇪🇸 Španělsko
Země původu
🇮🇹 Itálie
Zveřejněno
2008-05-02

⚠️ Riziko

The product poses a risk of injuries because it does not withstand the static strength test which could lead to falls. The test was carried out on the major axis, and it was noted that the connectors break when the following forces are applied:- force of the major axis with the gate pen: 6.1 KN (required level: 7 KN)- force of the major axis with the gate closed: 18.6 KN (required level: 22 KN).

Opatření

Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Withdrawal from the market ordered by the authorities.Date of entry into force: Unknown

Oval carabiner. The packaging is a plastic bag attached to card on which the details of the manufacturer are printed.