Electric massage machine - Figure improving exercise machine
CRAZY FIT MASSAGE

- Číslo případu
- 0743/08
- Kategorie
- Electrical appliances and equipment
- Typ / Model
- Crazy Fit Massage CFM-005, RC 01
- Cílová skupina
- Consumer
- Notifikující země
- 🇫🇷 Francie
- Země původu
- 🇨🇳 Čína
- Zveřejněno
- 2008-07-11
⚠️ Riziko
The product poses a risk of electric shock because: - the design of the transformer mounted on the electronic board does not meet the requirements for safety transformers according to IEC 61558-2-6. In particular, the creepage distance between the primary and secondary windings, measured at 3.4 mm, is below the prescribed minimum of 6 mm, and the secondary voltage is accessible to the user. - on the electronic board, the creepage distance between the very low voltage section, which is accessible to the user, and the mains voltage section (3.2 mm) is below the prescribed minimum for reinforced isolation (5 mm).The product does not comply with the relevant European standard EN 60335.
Opatření
Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Sales ban and withdrawal from the market and recall from consumers ordered by the authorities.Date of entry into force: Unknown