Fire

Recessed luminaires

SIRIUS LIGHTS
Recessed luminairesRecessed luminaires
Číslo případu
0675/08
Kategorie
Electrical appliances and equipment
Typ / Model
“Mars system moons” with following numbers: 017513, 017725, 017953, 017943, 017793, 017853, 017903, 017905, 017875, 017705, 017675, 017933, 017945, 017913, 017893, 017935, 017955, 017915, 017925, 017775, 017845
Cílová skupina
Consumer
Notifikující země
🇧🇬 Bulharsko
Země původu
🇧🇬 Bulharsko
Zveřejněno
2008-06-27

⚠️ Riziko

The product poses a risk of fire because the halogen lampholder for 220V is identical to lampholders intended for extra low voltage (≤50 V). Lampholders initially intended for extra low voltage should not be used for luminaires intended for use with tungsten halogen lamps with a voltage greater than 50 V. The product does not comply with the relevant European standard EN 60598.

Opatření

Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Withdrawal from the market ordered by the authorities.Date of entry into force: Unknown

The recessed luminaires are supplied with halogen lamps with a reflector, technical data: 220 V-240 V, 50-60 Hz, 50 W; a pin cap, the space between the pins is around 6 mm, and a plug with the following technical data: 24 V 250 W for luminaires No. 017725, 017943, 017853, 017903, 017905, 017875, 017933, 017945, 017935, 017955 and 017915; and25 V 100 W for luminaires No. 017953, 017793, 017705, 017675, 017913, 017893, 017925 and 017845.