Electric shock

Portable lamp - Bunky Bedside Light

BUNKY
Portable lamp - Bunky Bedside LightPortable lamp - Bunky Bedside Light
Číslo případu
1037/08
Kategorie
Lighting equipment
Typ / Model
Models No: 6910 and 6910R
Cílová skupina
Consumer
Notifikující země
🇬🇧 Spojené království
Země původu
🇨🇳 Čína
Zveřejněno
2008-09-19

⚠️ Riziko

The product poses a risk of electric shock because: - the insulated sleeve covering a joint in the live lead is not reliably held in position, - the top section of the ballast can be separated from the lower section while replacing the tube. This exposes the internal wiring of the lamp-holder, - the on/off switch is wired to the neutral. The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.

Opatření

Type of economic operator taking notified measure(s): OtherCategory of measure(s): Voluntary withdrawal from the market and recall from consumers by the importer.Press release has been issued.Date of entry into force: Unknown

Flexible arm, bunk-bed light. Packed in a cardboard box with a picture of the product on the front and a clear window.