Fire

Gas boiler - Nefit Topline, Buderus Logamax plus GB 162, Buderus Logano plus GB202

Nefit, Buderus
Gas boiler - Nefit Topline, Buderus Logamax plus GB 162, Buderus Logano plus GB202Gas boiler - Nefit Topline, Buderus Logamax plus GB 162, Buderus Logano plus GB202
Číslo případu
0392/09
Kategorie
Gas appliances and components
Cílová skupina
Consumer
Notifikující země
🇳🇱 Nizozemsko
Země původu
🇳🇱 Nizozemsko
Zveřejněno
2009-03-27

⚠️ Riziko

The products pose a risk of fire because, due to overheating of the burner seal, a leakage can occur between the burner housing and the heat exchanger. Through this opening flue gases can flow into the appliance. These flue gases can, after a period of time, lead to fire damage in or outside the appliances. The product does not comply with the Gas Appliances Directive.

Opatření

Type of economic operator taking notified measure(s): OtherCategory of measure(s): Voluntary stop of sales and corrective actions.Date of entry into force: Unknown

<a href="http://ec.europa.eu/consumers/safety/rapex/docs/0392_09.pdf" target="_blank"> see attachment</a><img src="http://ec.europa.eu/consumers/images/pdf.gif" border="0"/>Gas boiler
Toxická DB:

Databáze toxických látek