Electric shock

Plug for non-heating appliances

Feiyu
Plug for non-heating appliances
Číslo případu
0664/09
Kategorie
Electrical appliances and equipment
Typ / Model
SKS01
Cílová skupina
Consumer
Notifikující země
🇩🇪 Německo
Země původu
🇨🇳 Čína
Zveřejněno
2009-05-22

⚠️ Riziko

The product poses a risk of electric shock because: - the creepage gap and air gap between the earthing and live components, measuring only 2.6 mm, is too small (minimum gap required is 4 mm), - the strain relief device, which is intended only for sockets and not for plugs, is faulty, - the appliance's plug-and-socket connection is not mechanically stable. After being put back together following connection to a mains lead, the two parts of the housing come apart, exposing live components and thus presenting a risk of electric shock. The product does not comply with the relevant European standard EN 60320.

Opatření

Type of economic operator taking notified measure(s): OtherCategory of measure(s): Voluntary withdrawal from the market and recall from consumers by the importer.Date of entry into force: Unknown

Plug for non-heating appliances. Marking on the plug: 10A, 250V~, L E N.