Electric shock, Fire

Electric fan

Baumann
Electric fanElectric fan
Číslo případu
1164/09
Kategorie
Electrical appliances and equipment
Typ / Model
FS-50
Cílová skupina
Consumer
Notifikující země
Cyprus
Země původu
🇨🇳 Čína
Zveřejněno
2009-08-28

⚠️ Riziko

The product poses a risk of electric shock and fire because:- the conductor of the supply cord has a nominal cross-sectional area of 0.43 mm instead of 0.5 mm; - the protective earthing conductor has a resistance value of 140 mΩ instead of 100 mΩ.The product does not comply with the Low Voltage Directive (LVD) and the relevant European standard EN 60335.

Opatření

Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Sales ban ordered by the authorities.Date of entry into force: Unknown

Oscillating, 3-speed, electric fan with a floor stand.