Electric shock, Fire

Electrical supply cord

Youzhi Dianxian
Electrical supply cord
Číslo případu
1061/10
Kategorie
Electrical appliances and equipment
Typ / Model
Unknown
Cílová skupina
Consumer
Notifikující země
🇷🇴 Rumunsko
Země původu
🇨🇳 Čína
Zveřejněno
2010-07-16

⚠️ Riziko

The product poses a risk of electric shock and fire because the insulation cord can melt and catch fire due to the following contraventions:- the supply cord does not include an earth protection conductor. - the size of the cross section of each conductor is 0.133 mm² (must be at least 0.75 mm²) ;- the electrical resistance is different from what is required in the standard.One accident reported. The product does not comply with the Low Voltage Directive (LVD).

Opatření

Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Sales ban and withdrawal from the market ordered by the authorities.Date of entry into force: Unknown

White plastic body with three sockets for plugs and a red switch. The cord itself is 3 m long. The product is packed in a transparent polyethylene film. A blue and yellow label is attached to the polyethylene packaging with metal staples. Rated voltage (16 A/250 V).